Remove battery
compartment
clearance
To tamper proof the product i.e. prevent unauthorised adjustment of
value.
1. Internal temperature sensor has failed.
2. Ambient temperature is outside product operating temperature range.
E I
life remaining) the battery symbol will flash in the display, it is
recommended to change the batteries during this period.
Remove the battery compartment by pinching the tabs and
withdrawing downwards. Replace the spent batteries with 2 x AA 1.5V
alkaline batteries ensuring correct orientation. Replace the battery
compartment pressing fully home.
The green LED will be on when there is a demand for heating, and
off when there is no demand.
The red LED will flash for 7 seconds, approximately every 5
minutes. This denotes that a radio signal is being received from
the Digistat+RF unit.
Situations Requiring Attention
approaching the end of their life (see ‘battery replacement’).
signal from the Digistat+RF unit. This may be caused by the
batteries being dead (see ‘battery replacement’) or some
temporary interference with the radio signal.
the battery drawer, after a few seconds (the display will go blank)
close the battery drawer and then reset to your desired
temperature. If the radio signal has been successfully transmitted
and received, the red LED will flash for 7 seconds then go off.
require the attention of a heating engineer/electrician.
the red LED will stay on until a satisfactory signal is reinstated.
automatically reset itself for normal operation.
Combi boiler basic wiring layout
Zone control basic wiring layout
Standard for all models
If more than one ‘wireless system’ is fitted within the same property.
1. Install (see installation instructions) and turn power on to the
switched on. The red LED should come on.
also come on. Check to see if the boiler and/or motorised valve
are working.
3. To enter ‘learn’ mode push the button marked 1 followed by 2
learn mode. Release both buttons.
4. The red and green LED’s should both now be on.
than one metre).
6. Insert the batteries into the holder and slide them into the Digistat
RF until the drawer clicks into place.
7. The Digistat RF should now display the actual room temperature.
If the unit has been stored in a cold place, it may take time to
warm up.
8. As soon as the battery compartment is slid back into place, the
The green LED may be on or off depending on the room
temperature at the time of commissioning.
9. If the red LED remains on, slide down the battery drawer on the
Digistat RF, check the battery positions are correct, and once the
display has faded, repeat steps 6 to 8.
dial clockwise until a flame symbol appears, in the left hand
segment of the display.
that the radio signal is being sent and received. After 7 seconds
the red LED should go out and the green one come on.
12. Check to confirm that the boiler and/or motorised valves are
working.
dial anticlockwise until the flame symbol disappears.
seconds both the red and green LEDs should go out. Check that
the boiler and/or motorised valve have powered down.
confirmed the system operates correctly, fit and secure the
Digistat RF to the wall (see installation instructions).
seconds each time a radio signal is received from the Digistat RF. This
will occur approximately every 5 minutes.
replacement Digistat RF or SCR is fitted.
must arrange for a competent electrician to install it for you. Wiring
must conform to the current IEE regulations.
is switched off.
Installation Instructions
Read all installation and commissioning instructions before
proceeding.
Do not switch on until ready to commission.
The system wiring must be able to be fully disconnected from the
mains supply by a switch incorporated in the fixed wiring having a
contact separation of at least 3mm on both poles. Fused at 3A.
position, close to the combi boiler or central heating system wiring
where it is surrounded by metal objects or mains voltage cable, as this
may interfere with the radio signal).
For the best performance install in an open space, at least 30cm
distance from any metal objects including wall boxes and boiler
housing.
final location of the Digistat +RF room thermostat and not less than
30cm from the boiler side panel.
Warning: Installing the SCR too close to the metal side panel or
mains cables may interfere with the radio signal.
1. Loosen the securing screws, remove the wallplate, and if surface
wiring is to be used, snap out the cable entry strip on the bottom
edge of the wallplate with a pair of pliers.
2. Fix the wallplate, terminals at the top, either direct onto the flat
wall using wall plugs and no 6 x1” wood screws or on a flush
wallplate clearances are shown.
relevant diagram, to comply with current IEE regulations.
N L 1 2 3 4
50 mm
minimum
clearance
40 mm
minimum
clearance
40 mm
minimum
clearance
70 mm
minimum
SCR wallplate clearances
This product is double insulated and does not require an earth
be wired in to replace hard wired room or programmable thermostats
shown on the system or boiler wiring diagrams. Always check other
manufacturers instructions for compatibility.
To cancel the Preset Mode & return to normal operation
You can either,
1. If you want to return to your previous setpoint (before you entered
be cancelled and the product will return to normal operation and the
display will show the current room temperature as shown,
22
ºc
2. If you want to set a new setpoint, just rotate the dial until your
required setpoint is shown on the display. After a couple of seconds
the display will change to show the current room temperature as
shown,
22
ºc
To change the user adjustable settings
temperature setting) will be displayed and if turned one more click
Changing the Preset Temperature
I5
ºc
SET
menu as described above, then rotate the dial clockwise until ‘HI’
is showing.
H I
30
ºc
H I
Changing the Minimum Temperature Setting
menu as described above, then rotate the dial clockwise until ‘Lo’
Is showing.
5
ºc
While adjusting the settings within the menu, when you reach the
maximum or minimum possible setting the display will flash to
indicate you cannot adjust the product further, e.g. you cannot set
more than 5sec or wait for 1 minute and it will return automatically.
BOILER
30cm Min
Preferred side of boiler
The range may be affected by
composition/density and number of walls
between the Digistat +RF and SCR
Radio Signal Range:
30m Typically
SCR
Electrical
1. Internal temperature sensor has failed.
2. Ambient temperature is outside product operating temperature range.
E I
2

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Drayton Digistat plus 30002 - RF601 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Drayton Digistat plus 30002 - RF601 in de taal/talen: Engels als bijlage per email.

De handleiding is 4,46 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info