481299
6
Verklein
Vergroot
Pagina terug
1/9
Pagina verder
4
EN
ES
FR
IT
DE
PT
PL
CZ
RU
CR
HU
TR
NL
GR
SV
FI
NO
DK
RO
BG
EE
LV
SK
SI
Taking out the power cord
3
1
2
Air inlet grille
Front panel
Earth line
Terminal
block
Cord clamp
Screw
Screw
Screw
Power cord connect cover
Power supply cord
Stripping length of the power supply cord
N
L
40 mm
10 mm
30 mm
10 mm
Earth line
NOTE
• Use stranded wire only.
• Wire type : H07RN-F or more
For the air conditioner with the power supply cord
If the power supply cord is damaged, it must be replaced by the
manufacturer, the service agency, or another similarly quali ed person in
order to avoid hazard.
Put the power supply cord through
the notch.
Notch
CAUTION
1
2
3
4
1
2
3
4
80 mm
10 mm
10 mm
10 mm
70 mm
50 mm
Connecting
cable
Terminal cover
Cord clamp
Terminal block
Earth line
Connecting
cable
Screw
Screw
about 1
5
cm
Earth line
Stripping length of
the connecting cable
Screw
Wiring Connection
Wiring of the connecting cable can be carried out without removing the
front panel.
1. Remove the air inlet grille.
Open the air inlet grille upward and pull it toward you.
2. Remove the terminal cover and cord clamp.
3. Insert the connecting cable (according to the local cords) into the pipe hole
on the wall.
4. Take out the connecting cable through the cable slot on the rear panel so
that it protrudes about 15 cm from the front.
5. Insert the connecting cable fully into the terminal block and secure it tightly
with screws.
6. Tightening torque : 1.2 N·m (0.12 kgf·m)
7. Secure the connecting cable with the cord clamp.
8. Fix the terminal cover, rear plate bushing and air inlet grille on the indoor
unit.
How to connect the connecting cable
Be sure to refer to the wiring system diagram labeled inside the front
panel.
Check local electrical cords and also any speci c wiring instructions or
limitations.
CAUTION
How to install the air inlet grille on the indoor
unit
• When attaching the air inlet grille,
the contrary of the removed
operation is performed.
NOTE
• Use stranded wire only.
• Wire type : H07RN-F or more
Rear right
Rear left
g
nittuc-eiD
tils l
e
na
p
t
n
o
rf
g
n
i
gn
a
hC
e
s
oh niard
noitaraperp g
ni
p
i
P
Bottom left
Left
Bottom right
Right
Piping and Drain Hose Installation
* Since dewing results in a machine trouble, make sure to insulate both con-
necting pipes. (Use polyethylene foam as insulating material.)
Piping and drain hose forming
1. Die-cutting front panel slit
Cut out the slit on the leftward or right side of the front panel for the left or
right connection and the slit on the bottom left or right side of the front panel
for the bottom left or right connection with a pair of nippers.
2. Changing drain hose
For leftward connection, bottom-leftward connection and rearleftward con-
nection’s piping, it is necessary to change the drain hose and drain cap.
Heat insulator
Drain hose
How to remove the drain hose
• The drain hose can be removed by removing the
screw securing the drain hose and then pulling out
the drain hose.
• When removing the drain hose, be careful of any
sharp edges of steel plate. The edges can injuries.
• To install the drain hose, insert the drain hose
rmly until the connection part contacts with heat
insulator, and the secure it with original screw.
(3) Slightly open the lower part of the front panel, then pull the upper part of the
front panel toward you to remove it from the rear plate.
(4) After removing the front panel, remove the power cord connect cover and
the cord clamp.
(5) Connect and secure the power supply cord and secure the cord clamp and
the power cord connect cover.
(6) Put the power supply cord through the notch.
(7) Be sure to smooth the notch with a le, etc.
1
2
4
3
1
2
3 4
80 mm
10 mm
10 mm
10 mm
70 mm
50 mm
Connecting
cable
Terminal cover
Cord clamp
Terminal block
Earth line
Connecting cable
Screw
about 15 cm
Earth line
Stripping length of
the connecting cable
Screw
42NQ009
42NQ012
1110251161-EN.indd 41110251161-EN.indd 4 12/28/07 6:10:50 PM12/28/07 6:10:50 PM
6

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Carrier 38NY009 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Carrier 38NY009 in de taal/talen: Engels als bijlage per email.

De handleiding is 1,37 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Andere handleiding(en) van Carrier 38NY009

Carrier 38NY009 Gebruiksaanwijzing - Nederlands - 4 pagina's

Carrier 38NY009 Gebruiksaanwijzing - English, Espanõl - 6 pagina's

Carrier 38NY009 Gebruiksaanwijzing - Alle talen - 52 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info