PART 5: USAGE
Press the ‘Up’ and ‘Down’ arrows to set desired temperature, and press heat to start the heater. Place lid on the
spa while heating. It can take 24-48 hours for your spa to reach its set temperature. See Part 4 for complete list of
Control Functions.
Lock the Buckle
Push the square pad upwards to lock and downwards to unlock.
Cleaning / Replacing Filter Cartridge
WARNING: RISK OF ELECTRIC SHOCK. Unplug the PCU before beginning spa maintenance.
NOTE: A dirty or incorrect lter cartridge may contaminate the spa water and cause
damage to the heating function.
1. Carefully thread the two inlet/outlet caps on inner spa wall. (Ensure the rubber gaskets are in
place within the plastic caps)
2. Remove lter housing lid by turning it anti-clockwise, then remove the lter cartridge.
3. Rinse off lter cartridge with water and reuse if possible. Remove and clean the white lter
grill (see photo opposite) - remember to replace lter grill after cleaning.
Replace lter if the cartridge remains dirty after rinsing or is badly discoloured.
4. Put the cleaned lter back into the cartridge housing and close the lid by turning it clockwise.
5. Remove caps from the two inlet/outlet caps on inner spa wall and allow water to ow into pump. Next
purge air from the air valve on the PCU. The tub is now ready for use.
PART 6: WATER MAINTENANCE
The lter cartridge should be cleaned weekly and replaced on a monthly basis, or
depending on use. A reminder (‘CHG FIL’) will appear to change the lter after 25 days.
Hold down ‘HEAT’ for 5 seconds to clear the message. Change water once a month or
depending on usage and use appropriate spa chemicals. Please pay attention to the
chemicals used and dosage. Spa damage resulting from misuse of chemicals is not
covered by the warranty.
Water Balance: We recommend you maintain your water balance: PH value: 7.2 - 7.6;
Free Chlorine: 2ppm - 3ppm; Alkalinity: 120-150ppm. Use a test kit to test your spa
water before each use of the spa, or at least once per week.
Water Sanitation: We recommend using Chlorine Granules to disinfect the spa water.
Spa Ball: We suggest you use a Spa Ball to help in the ltration of your spa.
Cleaning the Spa: Clean the spa with soap and water, then rinse.
Leave it outside to dry.
Repairs: Small holes or punctures can be repaired with the
repair kit that comes with the spa (glue not included)
Maintenance & Troubleshooting
:
PROBLEM
Cloudy water/
Foamy water
Odour
Eye skin/
irritation
POSSIBLE CAUSE
• High pH (test to verify)
• Poor ltration
• High dissolved solids
• High level of organic
contaminants
• Low pH and/or alkalinity
combined Chlorine due to
organic contamination
SOLUTION
Add pH down
Add Foam Free
• Empty spa and re-ll
• Increase the amount of
Chlorine
Add PH Booster
• Increase the amount of
Chlorine Granules
FREE
Water
Test
App
NOTE:
The massage system will stop automatically after 30 minutes of operation. You can re-activate the jet
function by pressing the ‘JETS’ button. NOTE: Heater will automatically turn on when jets turn off.
Heating and jet function cannot be activated at same time. When heating system is working, pressing the
‘JETS’ button will change heating mode into jet mode: heating and ltering are shut down, jet system is
activated. When jets are turned off, heating and ltering automatically resumes.
NOTE: Keeping jets on for a long period of time may cause spa water to lose heat.
Pressing ‘HEAT’ activates the heating and ltering system at the same time. The ‘HEAT’ button will display
a solid red light as spa water heats up. Once desired temperature is reached, the heater will go into standby
mode, which will be indicated with a ashing red light.
NOTE: Heater will not resume until spa water drops 2 degrees below set temperature for maximum
efciency. You can also manually restart the heater by pressing ‘HEAT’ when heater is turned off.
Jets Massage System
‘JETS’ Button: Press the ‘JETS’ button to activate the Jet Massage System on the spa. Pressing once will start
the lowest speed of the jets (L-1 will display on the screen). Press again to increase the speed of the jets to L-2, and
press again to reach the highest jet speed, L-3. Hold down the ‘JETS’ button for 5 seconds to turn jets off. When jets
turn off, ‘FIL’ will display on the screen to indicate the ltration and heat is back on. When jets mode is on it will ick
between the speeds (l-1, 2 & 3 & BUB).
NORMAL 41ºC 42ºC
L-1 L-2 L-3 FIL
Temp and Over-heat
cycle 41ºC and 42º C
‘Temp up’ Button: Press the ‘Temp’
up button for 5 seconds and hold and
temp will raise to 41ºC or 42ºC the
next cycle it will go back to the max
temp of 40ºC on the following cycle.
(10) (11)
GRAND RAPIDS SPA
6

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Canadian Spa Company Grand Rapids 2021 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Canadian Spa Company Grand Rapids 2021 in de taal/talen: Engels als bijlage per email.

De handleiding is 1,5 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info