4
7 6
10
9 1
2 3
8 5
1 2 3
4
7 6
10
9 1
2 3
8 5
1 2 3
P ackage Con tents
Diagrams and Lay out
- Keep the warranty statement on hand to r equest cover ed repairs .
- Unless clearly permitted in the product documentation, do not use
accessories (such as cables) other than those included in the package
with this product.
• Switch (main unit)..................................................................................................... 1
• AC adapter................................................................................................................... 1
• Po wer cable................................................................................................................. 2
• Po wer cable r etaining band.................................................................................. 1
• Rubber feet.................................................................................................................. 4
• Serial number stickers............................................................................................. 2
• Quick Setup Guide (this document)................................................................... 2
• W arran ty statemen t................................................................................................. 1
• Limited lifetime warran ty....................................................................................... 1
2018.05
Quick Setup G uide
BS-GU2005P
1. PoE Limit LED
On (amber): PoE is supplying mor e than 30 watts of pow er to all
devices. F or temper atures abov e 45°C (113°F), don ’t c onnect devices
that draw more than 30 w atts of P oE power total .
Blinking (amber): PoE power has been disabled t o some ports
because the maximum 50 watts of P oE power has been ex ceeded .
PoE po wer was disabled f or ports in order of descending por t
number until the total P oE output power w as 50 watts or less.
Off : PoE is feeding 30 w atts or less; or P oE power is disabled .
2. Loop LED
Blinking once per second (red): Loop blocked .
Off : T he switch is in normal operating condition.
3. Po wer LED
On (green): P ow er is on.
Off : Pow er is off .
4. PoE LEDs
On (green): P oE pow er is available.
On (amber): Overcurrent, ex cessive po wer draw or an y other error .
Off : PoE pow er is disabled.
5. 1000 Mbps LEDs
On (green): 1000 Mbps link.
Blinking (green): Loop prev ention is working.
Off : 100 Mbps, 10 Mbps link, or no link .
2 mm (0.08 in)
T echnical Specifications
Loop Pr ev ention
This unit can detect and prevent network loops that can cause
interference in the network.
What Is a L oop?
If both ends of an Ethernet cable are connected to the same hub , or
when multiple connections exist between two hubs, data may be sent
in a loop around the network, never getting to its destination and thus
wasting network capacity . This continuously circulating data may
interfere with other network communication.
Loop Pre vention
Off : Loops are not blocked .
On : If a network loop is detected, the port will be blocked until the loop
is fixed. A lso, the loop , link/ac t, and 1000 Mbps (if active) LEDs for
the blocked port will blink once per second.
T urning Loop Preven tion On and Off
Use the switch on the front of the swit ch to turn loop preven tion on and
off .
When a Loop Is Detected
Reconnect your Ethernet cabling, making sure that there ar e no
redundant connections.
Check Buffalo ’ s website or the pr oduct catalog for information about
the latest products or compatible models .
T roubleshooting
If you are unable to connect to a network, check the following:
• Are the A C adapter and the power cable c onnected correctly? Also, is
the power cable plugged into an outlet or sur ge protector?
• Is the Ethernet cable connected correctly? Are any cables
disconnected or broken?
• Is the link/act LED on? If not, manually set the communication mode of
the connected hub or LAN adapter to 100M half-duplex or 10M
half-duplex.
* This unit automatically detects and adjusts for str aight or crossov er
Ethernet cables, so either type of cable may be used.
** Site-terminated Ethernet cables are not recommended. A lways use
pre-assembled cables.
*** This function automatically recogniz es the port link status and
Ethernet cable length and adjusts the operating power ac cordingly .
Caution:
- While loop preven tion is enabled, the switch will send a loop detection
packet through the network every two seconds. If these packets disrupt
your network in any wa y , disable loop preven tion.
- Loop prev ention cannot detect or block all types of loops.
Installation
Precautions for Installa tion
• Do not install the device in an unstable location such as on an
unsteady table or an inclined surface.
• Do not place another hub or object that generates heat on top of this
unit.
• Please route all cables pr operly to preven t people from tripping over
them.
• Ensure the air vents on the pr oduct are not blocked by other
equipment or walls.
• Only use the AC adapter included with the pr oduct. Using other AC
adapters may result in damage or fir e.
Floor or Shelf Mounting
Attach the supplied rubber feet t o the bottom corners of the unit befor e
use.
Mounting to a Metal Surface
T o mount to a metal surface on a steel desk, use the “BS-MGK-A Magnet
Kit ” sold separat ely (Size: φ17×H3 mm, 4 pcs).
W all Mounting
T o mount the unit directly onto a wall, use 2 scr ews (not included) with
the dimensions shown below . I nstall the screws 110 mm (4.33 in) apart
and slide the mounting holes into the base of the switch ov er them.
- The scr ew head should project out from the wall
at 3 mm (0.12 in) as shown on the right.
- Do NOT use the scr ews included with this
product. The included scr ews are not designed
for wall mounting .
Standards
IEEE 802.3ab (1000BASE- T ), IEEE 802.3u (100BASE- T X),
IEEE 802.3 (10BASE- T ), IEEE 802.3af (PoE)
Flow C ontrol
IEEE 802.3x (when operating at full duplex)
Back pressure (when opera ting at half duplex)
Ports
PoE ports: 4
Uplink ports: 1
All ports suppor t Auto MDI- X.
Compatible Cables
(*)(**)
1000BASE- T: Enhanced category 5 or higher
UTP/STP cables
100BASE- T X: Category 5 or higher UTP/STP
cables
10BASE- T: Category 3 or higher UTP/STP cables
PoE: C ategory 5 or higher UTP/STP cables
Connector RJ-45 8-pin connector (Shield type)
Po wer Supply AC 100-240 V 50/60 H z
Po wer Consumption Max. 61 W
External Dimensions
177 x 31 x 103 mm; 6.97 x 1.22 x 4.06 in
(excluding pr otruding parts)
W eight 0.5 kg (1.1 lb.)
Operating
Environment
Operating temperatur e:
0–50°C (32-122°F) with PoE supplying less than 30 w atts
0–45°C (32-113°F) with PoE supplying less than 50 w atts
Operating humidity: 10–85% (no condensation)
Acquir ed Standards CE
T ransmission Speeds
1000 Mbps (1000BASE- T )
100 Mbps (100BASE- T X)
10 Mbps (10BASE- T )
Switching Method Store and f orward
Jumbo Fr ames
9,198 bytes
(14 bytes header + 4 bytes FCS ar e not included)
T ransmission
Encoding Method
8B1Q4/4D-P AM5 (1000BASE- T )
4B5B/ML T -3 (100BASE- T X)
Manchester encoding (10BASE- T )
Access Method CSMA/CD
Data T ransfer Speed
( Throughput)
1,488,095 packets/second (1000BASE- T )
148,810 packets/second (100BASE- T X)
14,881 packets/second (10BASE- T )
Switching F abric 10 Gbps
MAC Address T able 2,048 (self-learning)
Buffer Memory 128 Kbytes
Aging T ime Approx. 300 sec onds
Other Functions
PoE
Loop prev ention
Po wer saving (***)
Current C onsumption
Max. 1.2 A
When operating at 45°C (113°F) or abov e:
15.4 watts per port, 30 watts total
When operating at below 45°C (113°F):
15.4 watts per port, 50 watts total
Alternative A
T ransmission Distance
Max. 100 m
φ6 mm (0.24 in) 3mm (0.12 in)
Use screws wher e this section is 2 mm
(0.08 in) or less.
6. Link/Act LEDs
On (green): Link established.
Blinking (green): T ransmitting data or loop prevention is w orking.
Off : Link not established.
7. Loop prev ention switch
Switch loop prev ention on and off .
8. PoE ports
These Ethernet ports suppor t PoE. C onnect devices that need
Ethernet power to these ports. Each port can supply up to 15.4 watts.
The maximum total supply for all 4 ports will vary according to the
operating temperatur e. If it is below 45°C (113°F) , 50 watts . If it is
45°C (113°F) or above , 30 watts.
Connect Ethernet devices to the switch in ascending or der of port
number . I f the maximum total pow er for P oE ex ceeds 50 watts, po wer
to ports will be disabled in descending order by port number until
the total output power f or P oE is 50 watts or below .
All ports suppor t autonegotiation. The optimal duplex mode (full
duplex or half duplex) and transfer speed (1000, 100, or 10 Mbps) ar e
selected automatically .
9. Uplink port
Connect other hubs or switches to this port. This port doesn’ t
support PoE.
10. DC connector
Connect the included AC adapter to this c onnector . S ecure the A C
adapter cable with the retaining band.
W all
Max.3 mm
English
Caution:
- Do not put floppy discs, magnetic cards , or other magnetic storage media
near magnets. Doing so may delete or c orrupt data.
- If the switch is secured by the magnet kit alone, it should be no more than
75 cm (29.5 in) from the floor .
Italiano
C ontenuto della c onfezione
Diagrammi e la yout
- T enere la gar anzia a portata di mano per richiedere riparazioni coper te.
- Salvo specificamente consentit o nella documentazione del prodotto ,
non usare accessori (come ca vi) diversi da quelli inclusi nel pacchetto
di questo prodotto .
• Switch (unità principale )........................................................................................ 1
• Adattator e CA............................................................................................................. 1
• Cavo di alimen tazione............................................................................................. 2
• F ascetta di ri tegn o per ca vo di alimen tazione ............................................... 1
• Piedini in go mma...................................................................................................... 4
• Adesivi numeri di serie............................................................................................ 2
• Guida rapida di installazione (questo documento)...................... ............... . 2
• Garanzia........................................................................................................................ 1
• Garanzia a vita li mitata........................................................................................... 1
Guida rapida di installazione
BS-GU2005P
1. LED Limite P oE
Acceso (ambr a): alimentazione P oE per tutti i dispositivi supera i 30
watt. P er temperatur e superiori a 45°C (113°F), non collegare
dispositivi che assorbono più di 30 watt della P oE totale.
Lampeggiante (ambra): alimentazione P oE disabilitata per alcune
porte perché è stato superato il valor e massimo di 50 watt.
L ’alimentazione PoE è sta ta disabilitata per le porte in ordine
decrescente rispett o al numero delle porte fino a quando il suo
valore in uscita totale è pari o inf eriore a 50 watt.
Spento: alimentazione P oE uguale o inferior e a 30 watt, oppure
disabilitata.
2. LED ricircolo
Lampeggiante una volta al sec ondo (rosso): ricirc olo bloccato .
Spento: Lo swit ch è in condizione di funzionamento normale.
3. LED Alimentazione
Acceso (v erde): alimentazione attiv a.
Spento: alimentazione assente .
4. LED PoE
Acceso (v erde): alimentazione P oE disponibile.
Acceso (ambr a): sovraccarico , assor bimento eccessiv o di corrent e o
altri errori.
Spento: alimentazione P oE disabilitata.
5. LED 1.000 Mbps
Acceso (v erde): collegament o 1000 Mbps.
Lampeggiante (ver de): funzionalità antiricircolo non a ttiva.
Spento: 100 Mbps, collegamen to 10 Mbps o nessun collegamento .
2 mm (0.08 in)
Specifiche tecniche
F unzionalità antiricircolo
L ’unità può rilevare e prevenire i ricirc oli di rete che possono causare
interferenze nella rete .
Che cos’ è un Ricircolo?
Se entrambi i capi del cavo Ethernet sono collega ti allo stesso hub , o
quando esistono connessioni multiple tra due hub , i dati possono
essere mandati in ricircolo sulla r ete, non g iungendo mai a destinazione
e comportando quindi una perdita di capacità della rete. Il passaggio
continuo di dati può interferire con altr e comunicazioni della rete .
F unzionalità antiricircolo
Spento : ricircoli non bloccati.
Acceso : se viene rilevato un ricir colo di rete , la porta sarà bloccata fino
a quanto il ricircolo non viene eliminat o . Inoltre, i LED di
collegamento/azione e 1000 Mbps (se attiv o) per la porta
bloccata lampeggeranno una volta al sec ondo.
Attivar e e disattivar e la funzionalità antiricircolo
Usare lo switch ant eriore per attivar e e disattivare la funzionalità
antiricircolo .
Quando viene rilevato un ricir colo
Ricollegare i cavi Ethernet, assicurandosi che non ci siano connessioni
ridondanti.
V erificare sul sito di Buffalo o sul catalogo del pr odotto per informazioni
sui prodotti più recen ti o sui modelli compatibili.
Risoluzione problemi
Se non è possibile collegarsi alla rete , verificare che:
• L ’adattatore CA e Il cavo di alimentazione sono c ollegati
correttamente? Inoltre , il cavo di alimen tazione è collegato ad un ’altra
presa o ad un elemento di pr otezione?
• Il cavo Ethernet è collegato c orrettamente? Ci sono ca vi scollegati o
rotti?
• Il LED collegamento/azione è acceso? Se non lo è, impostar e
manualmente la modalità di comunicazione dell’hub collegato o
dell’adattator e LAN su 100M half-duplex o 10M half-duplex.
* L ’unità rileva e si regola automaticamente per i cavi Ethernet dritti o
incrociati, quindi è possibile usare qualsiasi tipo di ca vo .
** Cavi Ethernet interr otti non consigliati. Usare sempr e cavi preassembla ti.
*** Questa funzione riconosce automaticamente lo sta to del collegamento
della porta e la lunghezza del cavo Ethernet e adatta l’alimentazione di
conseguenza.
Attenzione:
- Quando la funzionalità antiricircolo è abilitata, lo switch in vierà un
pacchetto di rilevamento ricirc oli nella rete ogni due secondi. Se questi
pacchetti interferiscono in qualche mondo con la rete , disabilitare la
funzionalità antiricircolo .
- La funzionalità antiricircolo non può rilevare o bloc care tutti i tipi di ricircolo .
Installazione
Precauzioni per l’ installazione
• Non installare il dispositivo in una sede non stabile come ad esempio
un tavolo instabile o una superficie inclinata.
• Non posizionare un altro hub od oggetto che gener a calore al su
questa unità.
• Posizionar e adeguatamente tutti i ca vi per evitare che le persone vi
inciampino.
• Assicurarsi che gli sfiati di aerazione del pr odotto non siano bloccate
da altri dispositivi o da muri.
• Usare solo l’ adattatore CA f ornito con il prodott o. L ’uso di altri
adattatori CA può comportare danni o causare incendi.
Installazione a pavimento o su scaffale
Prima dell’uso attaccare i piedini in gomma inclusi negli angoli inf eriori
dell’unità.
Installazione su una super ficie metallica
Per installar e su una superficie metallica su un piano in acciaio, usare il
“BS-MGK-A Magnet Kit” venduto a parte (dimensione: φ17×H3 mm, 4
pz).
Installazione a parete
Per installar e l’unità direttamente su una par ete, usar e 2 viti (non incluse)
delle dimensioni indicate di seguito . Installare le viti a 110 mm di distanza
e far scorrere i f ori di montaggio nella base dello switch sopra di lor o .
- La testa della vite deve spor gere 3 mm dal muro
come mostrato a destra.
- NON usare le viti incluse con il prodott o . Le viti
incluse con il prodotto non possono esser e usate
per l’ installazione a parete .
Standard
IEEE 802.3ab (1000BASE- T ), IEEE 802.3u (100BASE- T X),
IEEE 802.3 (10BASE- T ), IEEE 802.3af (PoE)
Controllo flusso
IEEE 802.3x (per funzionamento full duplex)
Pressione post eriore (per funzionamento half duplex)
Por te
Porte P oE: 4
Porte Uplink: 1
T utte le por te supportano Auto MDI-X.
Cavi compatibili
(*)(**)
1000BASE- T: cavi UTP/STP migliorati di cat egoria
5 o superiore
100BASE- T X: cavi UTP/STP di categoria 5 o
superiore
10BASE- T: cavi UTP/STP di categoria 3 o superiore
PoE: ca vi UTP/STP di categoria 5 o superiore
Connettore Connettore a 8 pin RJ-45 (tipo schermo)
Alimentazione AC 100-240 V 50/60 H z
Consumo energetico Max. 61 W
Dimensioni esterne
177 x 31 x 103 mm; 6.97 x 1.22 x 4.06 in
(escluse parti sporgenti)
Peso 0.5 kg (1.1 lb .)
Ambiente operativ o
T emperatura di esercizio:
0–50°C (32-122°F) con alimentazione P oE inferiore a 30 w att
0–45°C (32-113°F) con alimentazione P oE inferiore a 50 w att
Umidità di esercizio: 10–85% (senza condensa)
Standard acquisiti CE
V elocità di
trasmissione
1000 Mbps (1000BASE- T )
100 Mbps (100BASE- T X)
10 Mbps (10BASE- T )
Metodo di accensione
Archivia e inoltra
Fr ame Jumbo
9,198 bytes
(intestazione 14 byte + 4 b yte FCS non inclusi)
Metodo di codifica
trasmissione
8B1Q4/4D-P AM5 (1000BASE- T )
4B5B/ML T -3 (100BASE- T X)
Codice Manchester (10BASE- T )
Metodo di accesso CSMA/CD
V elocità di
trasferimento da ti
(velocità effettiva)
1.488.095 pacchetti/secondo (1000BASE- T )
148.810 pacchetti/secondo (100BASE- T X)
14.881 pacchetti/secondo (10BASE- T )
Infrastruttura di scambio
10 Gbps
T abella indirizzo MAC
2.048 (apprendimento automa tico)
Memoria buffer 128 Kbytes
Periodo di aging Circa 300 secondi
Altre funzioni
PoE
F unzionalità antiricircolo
Risparmio energetico (***)
Consumo di corrent e
Max. 1,2 A
Se in funzione a una temperatura di 45°C (113°F) o superiore:
15,4 watt per porta, 30 watt totali
Se in funzione a una temperatura di 45°C (113°F):
15,4 watt per porta, 50 watt totali
Alternativa A
Distanza di trasmissione
Max. 100 m
φ6 mm (0.24 in) 3mm (0.12 in)
Usare le viti in cui questa sezione è di 2
mm o meno.
6. LED Collegamenti/Azioni
Acceso (v erde): collegament o stabilito .
Lampeggiante (ver de): trasmissione dati o funzionalità antiricirc olo
non attiva.
Spento: collegamento non stabilit o .
7. Loop prev ention switch
Attivare e disa ttivare lo Swit ch funzionalità antiricircolo .
8. Porte P oE
Queste porte Ethernet suppor tano PoE. C ollegare i dispositivi che
necessitano di alimentazione Ethernet a queste porte. Ogni porta
può fornire fino a 15,4 watt . L ’alimentazione massima complessiva
per tutte le 4 porte varierà in base alla temperatura di esercizio . S e è
inferiore a 45°C (113°F) , 50 watt . Se è 45°C (113°F) , 30 watt.
Collegare i dispositivi Ethernet allo switch in or dine crescen te
rispetto al numero delle porte. Se l’alimentazione complessiva
massima per il PoE super a 50 watt, l’alimen tazione alle porte sarà
disabilitata in ordine decresc ente rispetto al numero delle porte fino
a quando l’alimentazione totale in uscita per il P oE non è uguale o
inferiore a 50 watt .
T utte le por te supportano l ’autonego ziazione. La modalità duplex
ottimale (full duplex o half duplex) e la velocità di trasf erimento
(1.000, 100 o 10 Mbps) sono selezionate automaticament e.
9. Porta Uplink
Collegare altri hub o interrutt ori a queste porte. Questa por ta non
supporta il PoE.
10. Connettor e C C
Collegare a questo c onnettore all’ adattator e CA incluso. Vincolare il
cavo dell’ adattatore CA c on la fascetta di ritegno .
Par ete
Max.3 mm
Attenzione:
- Non mettere floppy disc , schede magnetiche o altri dispositivi di
archiviazione magnetici vicino alle calamite . Una simile operazione
potrebbe eliminare o danneggiar e i dati.
- Se lo switch è vincolato solo dal kit magnetico , non deve essere posizionat o
a più di 75 cm dal suolo.