686410
9
Verklein
Vergroot
Pagina terug
1/12
Pagina verder
CAUTION: YOU MUST ENSURE THE PUMP IS UNPLUGGED BEFORE BEGINNING SPA MAINTENANCE TO AVOID
RISK OF INJURY OR DEATH.
Filter Cartridge Maintenance
NOTE: To ensure your spa water stays clean,
check and clean your filter cartridges
every day follow the steps below.
NOTE: We recommend changing your filter cartridges every week or, if the filter cartridges remain soiled and discolored, they
should be replaced.
Water Maintenance
Keeping your SPA water clean and chemically balanced is necessary. Simply cleaning the filter cartridge is not enough for
proper maintenance,
we recommend you use pool chemicals to maintain water chemistry and chlorine or bromine tablets (do not
use granules) with the chemical dispenser.
Water quality will be directly related to frequency of use, number of users and overall maintenance of the spa. The water should
be changed every 3 days if there is no chemical treatment being performed with the water.
Note: We recommend you take a shower before using your Lay-Z-Spa, as cosmetic products, lotions, and other residues on the
skin can quickly degrade water quality.To use the chemical
dispenser
, please follow the below instruction.
MAINTENANCE
NOTE: Your spa will require additional air to be added from time to time. Changes in temperature from day to night
will change the pressure in the spa and may cause a certain amount of deflation. Please follow the Assembly
instructions and drain the spa before inflating to the accurate pressure needed.
11
Using chemical liquid (not included):
Using chemical tablets (not included):
Alarms
Solutions
Causes
Reasons
The water flow sensors
work without pressing the
filter or heat button.
1. The water flow sensor flags didn’t fall back
into the correct position.
2. The water flow sensors are broken.
1. Unplug the plug gently, strike the side of the pump but not violently, and
plug it back in.
2. Contact your local Bestway After Sales service point to get instructions.
After starting or during the
functions of filtering or/and
heating, the water flow
sensors do not detect
water flow.
1. You forgot to remove the 2 stopper caps from
inside the pool.
2. Filter cartridges are dirty.
3. Activate the filter or heat system and put your
hand in front of the outlet pipe inside the pool to
check if you can feel water flowing out.
a. If no water flows out the water pump is broken.
b. Water flows out but the alarm appears,
the water flow sensors are broken.
1. Remove the 2 stopper caps before heating, refer to Assembly section in the
User’s Manual.
2. Remove the filter set from inside the pool and push the filter or heat button. If
no alarm appears, clean or change the filter cartridges install the filter set
inside the pool.
3. Contact your local Bestway After Sales service point to get instructions.
The manual reset thermal
cut-out has problem.
The manual reset thermal cut-out trips off.
1. The ground bonding of your home has some
problem.
2. The pump has some problem.
1. Unplug the pump and push the reset button, then plug the pump back in.
2. In case the alarm still remains, check the RESET BUTTON section in
manual.
3. Contact your local Bestway After Sales service point to get instructions.
Contact your local Bestway Aftersales Service Center for instructions.
The pump’s thermometer
connections have issues.
1. The pump’s thermometer connectors don’t
work properly.
2. The pump’s thermometer is broken.
Contact your local Bestway After Sales service point to get instructions.
The pump’s thermometer
reads the water
temperature below
4°C (40°F).
1. The water temperature is lower than
4°C (40°F)
2. If the water temperature is higher than
7°C (44.6°F), the pump’s thermometer is broken.
1. The spa is not designed to operate with water temperatures lower than
4ºC (40°F). Unplug the pump and only re-start the pump when the water
temperature reaches 6°C (43°F).
2. Contact your local Bestway After Sales service point to get instructions.
The pump’s thermometer
reads the water
temperature over
50°C (122°F).
1. The water temperature is over 50°C (122°F)
2. If the water temperature is lower than
45°C (113°F), the pump’s thermometer is
broken.
1. The spa is not designed to operate with water temperatures greater than
40°C (104°F). Unplug the pump and only re-start the pump when the water temperature
reaches 38°C (100°F) or lower.
IMPORTANT: Before you re-start the pump, push the pump’s reset button.
2. Contact your local Bestway After Sales service point to get instructions.
Ground Connection Failed.
P6653
Filter Set
58323
Filter Cartridge
C
o
n
-
l
o
i
n
5
-
l
o
i
n
5
s
e
c
.
303021185661/14x21cm/54112; 54113; 54123; 54129; 54148; 54154; 54171; 54174; 54175; 54183; 54186/欧规AirJet SPA说明书/
9

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Bestway 54113 Lay-Z-Spa - Monaco AirJet bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Bestway 54113 Lay-Z-Spa - Monaco AirJet in de taal/talen: Engels als bijlage per email.

De handleiding is 40,79 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Andere handleiding(en) van Bestway 54113 Lay-Z-Spa - Monaco AirJet

Bestway 54113 Lay-Z-Spa - Monaco AirJet Gebruiksaanwijzing - Nederlands - 12 pagina's

Bestway 54113 Lay-Z-Spa - Monaco AirJet Gebruiksaanwijzing - Deutsch - 12 pagina's

Bestway 54113 Lay-Z-Spa - Monaco AirJet Aanvulling / aanpassing - Alle talen - 2 pagina's

Bestway 54113 Lay-Z-Spa - Monaco AirJet Snelstart handleiding - Alle talen - 40 pagina's

Bestway 54113 Lay-Z-Spa - Monaco AirJet Gebruiksaanwijzing - Alle talen - 196 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info