577843
3
Verklein
Vergroot
Pagina terug
1/14
Pagina verder
Quick reference guide
BENNING SUN 2
Important information
m
Please read the detailed operating manual (see PDF file on
CD-ROM) before using the BENNING SUN 2.
The BENNING SUN 2 must be operated by qualified techni-
cal personnel only.
m
Only use the temperature sensors and connecting cables
included in the scope of delivery of the BENNING SUN 2.
c
Do not apply any electrical contact between the tempera-
ture sensors and bare live parts.
m
The BENNING SUN 2 is intended for measurements under
dry ambient conditions only.
m
The BENNING SUN 2 is supplied by means of two 1.5 V
mignon batteries (IEC LR6). It is allowed to use alkaline re-
chargeable NiCd or NiMH batteries.
Switching the device ON/OFF
Press the
3
key and the
4
key at the same time to switch the
device ON or OFF. After having switched the device ON, it is set to the
mode for measuring the insolation, the angle of inclination and the com-
pass bearing. Without pressing a key, the device switches OFF automati-
cally after approx. 120 seconds (APO, Auto-Power Off).
HOLD function
Press the
7
key to store the displayed values in the LC display for
max. 120 seconds. The HOLD indicator
8
conrms that the values are
stored. Press the
7
key again to switch back to the measuring mode
Data logger (5000 data records) with real-time clock for storing
the insolation and the module / ambient temperature
occupied
memory space battery voltage
free memory
space
measuring interval
(1 min. to 60 min.)
alternating display
└──────────────┘
Data logger set-up
1. Press the
7
key (LOG) for > 5 seconds to activate the data
logger. Display: "LOG"
Alternately, the display shows the occupied / free memory space
as well as the battery voltage / the measuring interval in min-
utes.
2. Press the
7
key (LOG) again for > 5 seconds to set the
measuring interval. Display: "Int"
Press the
4
or
5
keys to increase or decrease the mea-
suring interval (1 minute to 60 minutes) in increments of one
minute.
3. Press the
3
key to display the memory mode. Display: "dAtA"
Press the
4
or
5
keys to select "StOP" (if the memory
is full) or "rOLL" (if you want to overwrite the oldest measured
values continuously).
4. Press the
3
► key again to delete the memory. Display: "dEL"
Select "YES" or "nO" by pressing the
4
▲ or
5
▼ keys to de-
lete the memory.
5. By means of the
7
key (OK), the setting can be stored at any
time. Press the
3
key or the
4
key to exit the data logger.
Starting / stopping the data logger
1. Press the
7
key (LOG) for > 5 seconds to activate the data
logger. Display: "LOG"
2. Press the
7
key (LOG) again and then the
7
key (OK) to
confirm "run". The measured values are written into the internal
memory including a time / date stamp. The LC display goes out
and the device switches over into the energy-saving stand-by
mode.
3. Press any key to display the progress of the data logger. The LC
display goes on and then goes out again.
4. To stop the data logger, press any key to display the data log-
ger. Press the
7
key (LOG) and then the
7
key (OK) to
confirm "StOP". Press the
3
key or the
4
key to exit the
data logger.
Reading out the data logger via the USB interface
1.
Install the driver and download program from the CD-ROM once.
2. Connect the BENNING SUN 2 to your PC by means of the USB
connecting cable and switch the device ON.
3. Start the download program, select / refresh the COM port and
click "Download".
4. The download of measured values starts.
Setting the time and date
time / 24-hour display
day / month
year
Date and time
1. Press the
5
key to display the time / date on the LC display.
2. Press the
5
key again for > 5 seconds until the hour display
starts flashing.
3. Press the ►
3
key to select the time / date field (field is flashing).
4. Press the ▲
4
or ▼
5
key to increase or decrease the value.
5. Press the
7
key (OK) to store the setting.
Measuring ranges
Function Range
Insolation
Resolution / accuracy
100 Wm² - 1250 Wm²
1 Wm²/ ± (5 % + 5 digits)
Temperature (module / ambient)
Resolution / accuracy
- 30 °C to + 125 °C
1 °C/ ± 1°C
- 22 °F to + 257 °F
1 °F/ ± 1°F
Compass bearing (orientation)
Resolution / accuracy
0 ° to 360 °
1 °/ ± 10°
Inclinometer
Resolution / accuracy
0 ° to 80 °
1 °/ ± 2 °
02/ 2012
BENNING SUN 2
102/ 2012
BENNING SUN 2
602/ 2012
BENNING SUN 2
5
3

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Benning SUN 2 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Benning SUN 2 in de taal/talen: Nederlands, Duits, Engels, Frans, Italiaans, Spaans als bijlage per email.

De handleiding is 14,21 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Andere handleiding(en) van Benning SUN 2

Benning SUN 2 Gebruiksaanwijzing - Deutsch, English - 17 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info