630724
5
Verklein
Vergroot
Pagina terug
1/28
Pagina verder
5
Removing the appliance
Close the gas supply to the appliance and disconnect the
appliance from the electricity supply.
You can remove the appliance by pushing it upwards from the
bottom.
Set-up, gas and electricity connection
Gas connection
Installation must only be performed by an approved expert or a
licensed after-sales service engineer in accordance with the
instructions specified in the "Installation instructions".
For the licensed expert or after-sales service
Caution!
The setting values for this appliance are specified on the rating
plate on the back of the appliance. The gas type set in the
factory is marked with an asterisk (*).
If the star symbol appears next to the label "NG", the appliance
is set up for natural gas, and if it appears next to "LPG", the
appliance is set up for liquefied gas.
Caution!
Before connecting the appliance, check whether the local
connection conditions (gas type and pressure) correspond to
the appliance settings. If a change to the appliance settings is
necessary, make the change with the aid of the instructions in
the "Installation instructions".
Caution!
This appliance is not connected to a waste gas main. It must be
connected and commissioned in accordance with the
installation conditions. Do not connect the appliance to a waste
gas main. All ventilation regulations must be observed.
Caution!
The gas connection must be made via a fixed, i.e. not mobile
connection (gas line) or via a safety hose.
Caution!
If using the safety hose, ensure that the hose is not trapped or
crushed. The hose must not come into contact with hot
surfaces.
Caution!
The gas connection must have an easily accessible locking
device.
Safety information
The nominal operating pressure of the appliance is:
for natural gas (G20) 20 mBar, for natural gas (G25) 25 mBar,
for LPG (G30) 30 mBar, for LPG (G31) 37 mBar. The appliance
must be operated at these pressure values. All data on the
rating plate of your appliance relates to these pressure values.
The manufacturer is not responsible for results, performance or
any risk caused by operating the appliance at different values.
: If the gas pressure in your gas supply grid!
for natural gas (G20) is higher than 25 mBar, for natural gas
(G25) is higher than 30 mBar, for LPG (G30) is higher than 36
mBar, for LPG (G31) is higher than 45 mBar, you must use
your appliance in conjunction with a suitable gas regulator, for
safety reasons. Connection, maintenance and configuration of
the gas regulator must be performed by an authorised
installation expert. If you do not know the gas pressure in your
gas supply grid, please ask your local supply grid operator.
Faults in the gas installation/smell of gas
If you notice a smell of gas or faults in the gas installation, you
must:
: WHAT TO DO IF YOU SMELL GAS!
Escaping gas may cause an explosion.
If you smell gas or notice any faults in the gas installation:
Immediately shut off the gas supply or close the gas cylinder
valve.
Immediately extinguish all naked flames and cigarettes.
Do not use any light or appliance switches and do not pull
any plugs out of sockets. Do not use any telephones or
mobile phones within the building.
Open windows and ventilate the room.
Call the aftersales service or the gas supplier.
Electrical connection
Caution!
Have the appliance set up by your after-sales service. A 16 A
fuse is required for connection. The appliance is designed for
operation at 220-240 V.
If the electricity supply drops below 180 V, the electrical
ignition system does not work.
Any damage arising from the appliance being connected
incorrectly will invalidate the guarantee.
If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified persons
in order to avoid a hazard.
For the after-sales service
Caution!
The electrical connection must only be carried out by a
licensed service technician. Observe the instructions of the
relevant electricity provider.
Caution!
The appliance must be connected in accordance with the data
on the rating plate.
Caution!
The mains voltage must correspond to the voltage specified on
the label or rating plate.
Caution!
Only connect the appliance to an electrical connection that
meets the applicable provisions. The socket must be easily
accessible so that you can disconnect the appliance from the
electricity supply if necessary.
Caution!
Please ensure the availability of a multi-pin disconnecting
system.
Caution!
Never use extension cables or multiple plugs.
5

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Belion GK604ZG20 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Belion GK604ZG20 in de taal/talen: Nederlands, Engels als bijlage per email.

De handleiding is 1,64 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Andere handleiding(en) van Belion GK604ZG20

Belion GK604ZG20 Gebruiksaanwijzing - Nederlands, English - 20 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info