1. PARTS DESCRIPTION (FIGURE )
The product is shipped with the following items. Please check that they
are all included.
1. Cover; 2. Horizontal fine adjustment screw; 3. Vertical adjustment
screw; 4. Terminals; 5. Tamper switch (receiver only); 6. Gain lock
switch (receiver only); 7. Function indications (see figure below);
8. Mirror; 9. View finder; 10. Adjustment dial; 11. Shading plate.
12. Mounting plate; 13. Bracket; 14. 8 tapping screws (Ø 4 x 30);
15. 8 oval countersunk head screws.
Figure : Functions/indications of transmitter (TX) and receiver (RX)
1. Operation LED; 2. Beam power (H set at factory); 3. Beam channel
(channel 1 set at factory); 4. Sensitivity attenuation LED; 5. Alarm LED;
6. Beep (alignment tome) switch (OFF set at factory); 7. Response time
adjustment (50 msec. set at factory); 8. Monitor jack; 9. Memory LED;
10. Beam channel (frequency 1-4, channel 1 set at factory);
11. Environmental output selector (N/C set at factory); 12. Memory
selector (manual set at factory); 13. Remote-manual memory logic
switch (L set at factory); 14. Environmental output terminal;
15. Remote control input
terminal.
2. INSTALLING THE SENSORS
Guidelines when installing sensors
Figure : Dos and Donts on where to install the sensor. No obstruc-
tions (consider seasonal changes). Avoid strong light. Avoid splashing
the unit. Avoid unstable ground.
Figure : Calculating beam expansion (B). (A= protection distance) The
beam spread of each model type must be considered in order to avoid
potential reflection from the ground surface or nearby objects.
Figure : Recommended installation height.
Wiring the system
Connect power to both the transmitter and receiver. The wiring
depends on the number of sensors or zones. Wire size also depends
on the distance between the sensor and the control panel/power
source. The wiring must comply with NFPA-70 of the National Electrical
Code.
CAUTION: The signal output on the receiver cannot be used
independently for the upper/lower optics, only as a set. Outdoor
wiring should be in PVC if used below ground or use a burial
cable. Use conduit for above-ground wiring.
Figure : Examples of wiring.
Example 1: Standard connection.
Example 2: When two or more sensors are connected on the same
zone.
Example 3: When two or more sensors are on separate zones.
Example 4: Two-stacked standard connection.
Example 5: When the environmental module and manual alarm memory
are used.
Note: Refer to section 5 Function Descriptions for selecting the
beam frequency.
Figure : Wiring distance between the sensor and the control panel
(m)
Note 1: The maximum wiring distance when two or more sets are
connected is the value shown divided by the number of sets.
Note 2: The signal line can be wired up to approximately 1000 m
with AWG22 (diameter 0.65 mm) telephone wire.
Standby battery: Be sure that the control panel is equipped with an
adequate standby battery and charging circuit. Use 12 V (at least) NiCd
or lead acid battery with a minimum capacity of 0.5 AH.
Arranging the terminals (Figure )
1. Environmental NC or NO, 30 VAC/VDC 1A or less; 2. Alarm memory;
3. Remote reset switch; 4. Power and terminal.
Mounting the units
The units can be easily mounted on a pole or flat surface. Using the
adjustment dial and screws, adjust the mirrors vertically (A) and
horizontally (B) so that the unit can work in all directions (figure ).
See examples 1-3.
A: Installing a wall-mounted unit
1. Remove the cover by unscrewing the screw at the base of the cover
(figure ).
2. Loosen the screws that fix the sensor body on the mounting plate and
slide the plate downwards to detach it.
3. Make the holes in the wall. Use the mounting plate as a template to mark
the screw holes. Allow 20 mm above the plate and 25 mm below the
plate for ease of detachment after installation. Figure b 1: Wood wall.
2: Concrete wall: refer to specification of the securing plug used.
4. Install the sensor (figure c)
- Insert the mounting screws, leaving 15 mm exposed.
- Install the mounting plate on the exposed screws.
- Pull the wire through.
- Tighten the screws and plug the opening of the wire hole.
- Connect the terminal.
- Attach the cover.
Note: The unit cannot be installed in an outlet box. However, the
outlet box can be used for wire-lead.
B: Installing a pole-mounted unit
1-2.Same as for wall-mounted units (figure ).
3. Make a wiring hole in the pole and pull the wire through. Place a pole
cap on top of the pole. The unit mounts to a 42-44 mm O.D. (outside
diameter) pole. Use a RIGID CONDUIT or equivalent (figure d).
Drill a 6 mm hole trough the pole where the PE beam will be mounted for
wiring. File all debris and sharp edges around the hole to prevent rough
edges from damaging the wire.
4. Install the sensor on the pole (figure e , 1: Plug opening of hole):
- Attach U-brackets to the pole and secure it to the mounting plate
with screws.
- Attach the sensor body.
- Pull the wire through and plug the opening of the wire hole.
- Connect the terminals.
- Attach the cover (break the knockouts (2) on the cover to
adapt to the configuration).
C: Installing a back-to-back pole-mounted unit
Same as for Pole Mounting described above but attach four U-brackets
to the poles in two pairs, one on top of the other, facing opposite
directions (figure f).
3. SETTING-UP FUNCTIONS AND BEAM ALIGNMENT
1. Supply power to the unit with the cover removed
2. Set the function options. Refer to section 5 Function Description for
a detailed explanation of each option.
Location Function Function switches
TX : RX Beam channel ¨ 1 channel ¨ 2 channel
(frequency) ¨ 3 channel ¨ 4 channel
TX only Beam power ¨ High ¨ Low
RX only Beep alignment tone ¨ On ¨ Off
Response time ¨ 50 msec (standard)
adjustment ¨ 300 msec ¨ 700 msec
¨ Others
Environmental output ¨ NO ¨ NC
Alarm memory ¨ Auto-reset
¨ Manual ¨ High
¨ Low
¨ Unused
3. Adjust the optical angle (figure g) by looking through the view finder
on either side of the transmitter optical unit until the receiver is visible.
Repeat the procedure for lower optical units and then repeat on the
receiver.
1. View finder; 2. Horizontal fine adjustment screw; 3. Vertical adjust-
ment screw; 4. Adjustment dial.
4. Fine tuning (figure h ). The initial beam alignment can be achieved by
using the alignment tone indicator. 1. Sensitivity attenuation LED (lights
when the beam reception is below the minimal level); 2. Alignment tone
switch; 3. Monitor jack.
4.1 Attach the shading plates (stored on the sides of both TX/RX) to the
lower optics of both TX and RX.
4.2 Turn the receiver alignment tone switch to ON.
GB
4

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Aritech PB601 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Aritech PB601 in de taal/talen: Engels, Frans, Zweeds als bijlage per email.

De handleiding is 0,81 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info