Infrared Forehead
Thermometer
Model:UFR106
Instruction manual
Introduction
▲Your new Infrared forehead thermometer uses advanced infrared (IR) technol-
ogy to measure temperature instantly and accurately on the forehead or object.
▲Easy to use and less measurement time
This thermometer does not need to contact body or object to ensure the safety
and hygiene. Its ergonomic design makes this thermometer be simple and very
easy to check the temperature. It only takes 1 second to take measurement and
reading.
▲Body and object modes
This thermometer supports to measure temperature of body and object. Measur-
ing range of object mode is 0.0 to 100.0°C (32.0°F~199.9°F ). That means except
to take body temperature, it also supports to take the surface temperature of
object as below,
Surface temperature of milk in the bottle;
Surface temperature of baby bath;
Environment temperature.
▲Color visible indication of alarm and alarm sounds
When body temperature is over 37.5°C, color indicator will show red color and an
alarm sounds for 10 times.
▲Memory function
It stores up to 20 sets recent measurement data.
▲Auto power off
Automatically power off if left idle for Approx 60±20s.
▲Measurement
Measurement time interval in 1 second and the measurement distance is within
1~3cm.
Please read the manual carefully before you use the unit, and keep for future
reference.
▲Intended use :
The Infrared Thermometer is intended for the intermittent measurement and
monitoring of human body temperature from forehead or object. The device is
indicated for use by people of all ages at homecare and in hospital.
Safety Information
To assure the correct use of the product, basic safety measures should always
be followed including the warning and the caution listed in the instruction
manual :
WARNING: This alert identifies hazards that may cause serious personal
injury or death.
CAUTION: This alert identifies hazards that may causeminor personal injury,
product damage, or property damage.
Type BF applied part
Manufacturer
Direct current
Follow instructions for use
CAUTION: Consult accompanying documents
Specifies serial number
SN
The following symbols may appear in this manual, on the label,on the device, or on it's
accessories. Some of the symbols represent standards and compliances associated with
the device and its use.
Symbol descriptions
DISPOSAL: Do not dispose this product as unsorted municipal waste. Collection
of such waste separately for special treatment is necessary.
This thermometer is not intended to substitute for a consultation with your
physician.The forehead scan temperature serves as a reference only. It
cannot be a judgment on fever.
Basic safety precautions should always be observed, especially when the
thermometer is used on or near children and disabled persons.
Please place the device unreachable by young.
Avoid direct sunlight.
Do not touch the lens.
No modification of this device is allowed.
The swallowing of small parks like packing bag, battery,battery cover and so
on may cause the suffocation. .
Please do not use a dilution agent, alcohol or petrol to clean the unit. Please
treat is gently and prevent the falling from a high place.
Please do not immersed it in liquid.
Never leave battery in the battery compartment for a long time without use, as
they may leak and cause damage to the unit.
Please take off the battery if you do not intend to use within 3 months. Replace
with new batteries if the unit display a low battery symbol.
Do not mix the old and new batteries together.
Do not use during the transportation.
Product Structure
Battery Installation
Setting Mode
Classification
-Body
Celsius/ Fahrenheit/
-Display
WARNING:
1. Internally powered equipment;
2. Type BF applied part; .
3. Protection against ingress of water or Particulate matter: IP21;
4. Not category AP/APG equipment;
5. Mode of operation:Continuous operation.
The user must check that the equipment functions safely and see that it is in proper
working condition before being used.
Do not dispose of electrical appliances as unsorted municipal waste, use
separate collection facillities.Contact you local government for information
regarding the collection systems available. If electrical appliances are
disposed of in landfills or dumps, hazardous substances can leak into the
groundwater and get into the food chain, damaging your health and well-be-
ing.
Remove the battery cover from the battery compartment,insert the battery.
1. Remove the battery cover from .the battery compart-
ment as the arrow direction accordingly.
2. Insert 2 AAA powerful batteries into the compartment
and ensure each battery is in the proper direction,
Positive (+) and Negative (-) are displayed on the back
of battery cover.
3. Close the battery cover.
Low battery and replacement
When power on, the low battery symbol will display once the unit start to
work, and you must replace with new batteries, otherwise the unit can' t work.
Battery type and replacement
Please use 2pcs AAA identical 1. 5V alkaline batteries.
Do not use the batteries beyond their expiry date.
Please remove the batteries if you do not need to use for long time.
Dispose of the battery in accordance with all federal, state and local laws. To
avoid fire and explosion hazard, do not burn or incinerate the battery.
WARNING
How To Set
1. Mode setting:
Press SET Button when power on after you hear 1 beep, the screen will display
or , Mode will change between and .when the SET Button is pressed.It
will confirm the Body Mode automatically when you switch to , and confirm the
Object Mode automatically when you switch to . Then Mode setting is finished.
2. Unit setting:
Long press SET Button when power on after you hear 1 beep, the screen will
display or , Mode will change between and .when the SET Button is
pressed.It will confirm the Celsius Unit automatically when you switch to , and
confirm the Fahrenheit Unit automatically when you switch to . Then press
START/STOP Button make the confirmation selection, and after the selection is
completed, it will automatically enter the sound switch setting mode.
3. Sound switch setting:
Enter the sound switch setting mode, or is displayed on the screen and
flashes, press SET Button to select and press START/STOP Button to confirm
selection.
Note: The Body Mode is used to measure the forehead temperature, then the Object Mode
is used to measure the object temperature.
Body mode Object mode
1. Auto-sense Probe
3. Display Screen
4. SET Button
5. MEM Button
6. START/STOP Button
7. Battery Cover
2. 2-Color LED
Proper Use Of The Unit
Table*1 Body Site Normal Temperature Range
Pre-measurement
Note: Body Temperature at WebMD;
website: http://firstaid.webmd.com/body-temperature;retrieved at 2010 Jan 7.
About Normal Body Temperature&Fever
The temperature in the forehead and temple area differs from the internal
temperature, which is taken orally or rectally. Vasoconstriction, an effect which
constricts the blood vessels and cools the skin, can occur during the early stages
of a fever.In this case, the temperature measured by the Infrared thermometer
may be unusually low. If the measurement therefore does not match the patient's
own perception or is unusually low, re peat the measurement every 15 minutes.
As a reference, you can also measure the internal body temperature using a
conventional oral or rectal thermometer.
Body temperature can vary from one individual/person to next.
It also varies by location on the body and time of day. Below shows the statistical
normal ranges from different sites.
Please keep in mind that temperatures measured from different sites, even at the
same time, should not be directly compared. Fever indicates that the body
temperature is higher than normal. This symptom may be caused by infection,
overdressing or immunization. Some people may not experience fever even
when they are ill.
These include, but are not limited to, infants younger than 3 months old, persons
with compromised immune systems, persons taking antibiotics, steroids or
antipyretics (aspirin,ibuprofen, acetaminophen), or persons with certain chronic
illnesses. Please consult your physician when you feel ill even if you do not have
fever.
Note:
●If the readingis37.5°C(99.5°F ), the display will show together with green LED and 1 short
beep.
●If the reading is≥37.5°C(99.5°F)and43°C(109.4°F), the display will show together with
red LED and 10 short beeps.
●Only after the unit °C/°F start to flash again, it can continue to take measurement.
●As the forehead measurement temperature is likely to be affected by sweat, oil and the
surroundings, the reading shall be taken as a reference only.
●If the probe is placed at an angle close to the forehead measurement, the reading will be
affected by surrounding temperature.
●Babies' skin reacts very quickly in the ambient temperature. Therefore, do not take their
temperature with the non-contact thermometer during/after breastfeeding, because the skin
temperature maybe lower than the internal body temperature.
1).Press the START/STOP Button, all symbols appear on the
display, you can hear 1 short beep, then unit °C/°F on the
display start to flash.
2).Press the SET Button to select Body Mode ,the temperature
unit flashes.
3).Move the probe close to the forehead make sure the probe
is flat and take measurement with a distance between 1~3cm.
Press the START/STOP Button, The meter will take measure-
ment.
4).The measurement will be finished in 1 second, when it has
been completed you can hear 1 short beep, in the meantime,
the reading will appears on the display with green LED blinks.
As a Body Thermometer
尺寸:440*290mm 材质:80g书纸 单黑 折页(风琴折再对折)
切线 折痕线
1

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Alphamed UFR106 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Alphamed UFR106 in de taal/talen: Engels als bijlage per email.

De handleiding is 1,09 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info