108612
10
Verklein
Vergroot
Pagina terug
1/12
Pagina verder
- 10 -
GENERAL
Carefully read the following important information regarding
installation safety and maintenance. Keep this information
booklet accessible for further consultations.
The appliance has been designed as a exhausting version
(external exhaust), as a filter version (internal air recycle)
cooker hood or as use in homes with centralised vacuum
system.
SAFETY PRECAUTION
1. Take care when the cooker hood is operating
simultaneously with an open fireplace or burner that
depend on the air in the environment and are supplied by
other than electrical energy, as the cooker hood removes
the air from the environment which a burner or fireplace
need for combustion.
The negative pressure in the environment must not
exceed 4 Pa (4 x 10 -5 bar).
Provide adequate ventilation in the environment for a
safe operation of the cooker hood.
Follow the local laws applicable for external air evacuation.
If the power supply cable is damaged it must be replaced
with a cable or a special assembly; both of these are
available direct from the manufacturer or from its special
technical assistance service.
2. WARNING!!
In certain circumstances electrical appliances may
be a danger hazard.
A) Do not check the status of the filters while the
cooker hood is operating
B) Do not touch the light bulbs after appliance use
C) Flambè cooking is prohibited underneath the
cooker hood
D) Avoid free flame, as it is damaging for the filters
and a fire hazard
E) Constantly check food frying to avoid that the
overheated oil may become a fire hazard
F) Disconnect the electrical plug prior to any
maintenance
This appliance conforms to the European Directive EC/
2002/96, Waste Electrical and Electronic Equipment
(WEEE). By making sure that this appliance is disposed
of in a suitable manner, the user is helping to prevent
potential damage to the environment or to public health.
The
symbol on the product or on the accompanying
paperwork indicates that the appliance should not be
treated as domestic waste, but should be delivered to a
suitable electric and electronic appliance recycling
collection point.
Follow local guidelines when disposing of waste.
For more information on the treatment, re-use and
recycling of this product, please contact your local
authority, domestic waste collection service or the shop
where the appliance was purchased.
ENGLISH
INSTALLATION INSTRUCTIONS
• Electric Connection
The appliance has been manufactured as a class II,
therefore no earth cable is necessary.
The connection to the mains is carried out as follows:
BROWN = L line
BLUE = N neutral
If not provided, connect a plug for the electrical load
indicated on the description label. Where a plug is provided,
the cooker hood must be installed in order that the plug is
easily accessible.
An omnipolar switch with a minimum aperture of 3mm
between contacts, in line with the electrical load and local
standards, must be placed between the appliance and the
network in the case of direct connection to the electrical
network.
• The appliance must be installed at a minimum height of
700 mm from an cooker stove in case of a gashob or an
electrical hob.
If a connection tube composed of two parts is used, the
upper part must be placed outside the lower part.
Do not connect the cooker hood exhaust to the same
conductor used to circulate hot air or for evacuating fumes
from other appliances generated by other than an electrical
source.
INSTALLATION
The following instruction should be followed to carry out
the correct installation of the cooker hood.
1) Mounting of the cooker hood on the lower side of the
cupboard.
2) Selection of the version (extraction or filtration)
Mounting the cooker hood on the lower side of the cupboard.
This appliance must be fitted to a cupboard or other suitable
support. For fixing use 4 screws suitable for the cupboard,
using the hole in Fig.1. When mounting align the front of
the cooker hood to the door of the cupboard and regulate
the L wall spacer through the screws marked P (Fig. 2).
The rear of the appliance must then align with the cupboard.
EXTRACTION THROUGH AN OUTSIDE WALL
The appliance expels the fumes through an outside wall or
a duct. It is necessary to buy a telescopic pipe in
accordance with the standards in use (not inflammable
with diameter 150mm) and connect it to flange F (Fig. 3).
RECIRCULATION
To transform the cooker hood from the extraction version
to the re circulating one ask your supplier for an activated
carbon filter. The activated carbon filter cleans the air of
the room. This filter is not washable or re-usable and must
be substituted at least every 4 months. Saturation of the
activated charcoal depends on how often the appliance is
used, the type of kitchen and how regularly the grease
filter is cleaned. The filter must be fitted to the extracting
group cooker hood in the centre of the fan grille by twisting
it by 90 degrees until it is gripped securely. For this
operation remove the grill G (Fig. 2). The clean air is
10

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw ATAG WV 9111 LM bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van ATAG WV 9111 LM in de taal/talen: Nederlands, Duits, Engels, Frans als bijlage per email.

De handleiding is 0,15 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info