These operation instructions describe the functioning and the operating of the
Upsilon boilers. This manual is for the end user. For installation and servicing
there is an installation & servicing instructions manual for the installer.
Read this manual fully before operating the boiler. In case of doubt or errors
contact your installer.
A.O. Smith reserves the right to change the specications and dimensions
without prior notice.
Safety
The device may be operated only by authorized persons who have
been instructed on the operation and use of the device. Improper use
may cause damage to the device and / or to the connected installation.
The appliance is not to be used by children or persons with reduced
physical, sensory or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision or instructions.
Children being supervised are not to play with the appliance.
Work on the boiler must be carried out by a competent person, (Ref:
Gas Safe Register) using correctly calibrated instruments with current
test certication. When replacing parts use only A.O. Smith Service
parts. Contact details for A.O. Smith can be found on the back page
of this manual.
In case you smell gas:
- No naked ames! Do not smoke!
- Do not operate electrical switches for lights or any other appliance
- Do not use a telephone
- Turn off gas supply at meter
- Open windows and doors
- Notify any persons in the building and leave the building at once
- Call Gas company or installer only when outside the building
Protection for corrosion
Do not use any sprays, chlorine containing agents, solvents, paint etc. around
the boiler or around the air intake supply entrance of the boiler. These substan-
ces have negative inuences on the boiler and can lead to corrosion resulting
in failure of the boiler.
Checking the water pressure
Check the water pressure in the central heating installation regularly.
Use only potable water for lling.
Additives only after clearance by A.O. Smith.
Contact your installer in case of doubt.
Description of the boiler
The Upsilon boiler is a room sealed, condensing and modulating central heating
boiler and meets the European requirements (CE). A declaration of conformity
is available on demand from the supplier.
The efciency of the boiler is very high and the radiation convection and standby
losses very low. The emission of noxious substances is far below the xed
standards so the boiler meets the requirements of today.
If changes are made to the boiler construction the boiler no longer complies
with the CE requirements.
Information and operation of the boiler
Screen User manual
T3
DHW
230V~
AC
230V
out
230V~
AC
230V
out
L
N
L
N
L
N
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 2 3 4 5 6 7 8
NN
L
N
L
P3
Error
Heat
demand
LPG
On/Off
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
T10
End
switch
Blocking
Switch
Open-
Therm
LWCO
0-10Volt
230V Pump / 3-WV.230V Damper230V DHW pump230V out230V~ AC
T4
Out
On/Off
L
MBoiC
Keyboard Main switch
Screen
The LCD screen is backlit. The light is activated by pushing one of the buttons
There are 2 light colours available. The various colours indicate the following:
Blue Basic level
Red Problem display
Having pressed the last button, the screen light stays on for 2 minutes.
Screen explanation
9 10 11 12 13
1 5
2 6
3 7
4 8
1. CH-program active
2. DHW-program active
3. Clock program active (CH and/or DHW)
4. Pump continuously active or pumps active when frost protection
is active
5. Boiler off at:
outside temperature > T-day (when day temperature is active)
or > T-night (when night temperature is active)
6. System pump on
7. Burner on.
Starts ashing during ignition, continuous when burner is on.
8. Chimney sweep function (100% power for emission measurement)
. .. 9. Boiler address:
1 = Cascade Master
2..8 = Cascade Slaves
10. Identication burner inside boiler
11. Night temperature active
12. Day temperature active
13. 2 text lines with 8 characters each
The operational status, messages and possible errors are displayed
here.
Operational status
- Standby Standby. Boiler is ready for operation.
- Vent.Phase Ventilation stage
- Ignition phase Ignition stage
- Burner lit CH Burner active for heating
- Burner lit DHW Burner active for hot water
- CH T > Tset Burner off on account of too high ow temperature CH
- Overrun CH Overrun time pump over CH
- Overrun DHW Overrun time pump over DHW
- Service Boiler needs maintenance. Contact installer
- Frost Burner active for frost protection
Explanation keyboard
Value increase / change
Emission Back / correction
measurement
Backward Forward
Reset* Conrm selection
Value decrease / change
* Reset
Reset only functions in case of an Error or certain Messages. If reset is
rapidly pressed over a short period of time, the device will block comple-
tely. Only loss of power (main switch) will restart the device completely.
Recommendation: contact your installer and inform them about the fault and
give them the number code.
The main switch is located on the right hand side of the keyboard. This switch
controls the 230V power supply.
Standard read-out
Standard read-out: Good
we 10:17
Good indicates that the boiler operates normally (burner on
or off)
we 10:17 indicates the actual day and time.
The standard read-out offers 3 information screens.
Switching to different screen can be found using the + or -
button.
1. “Good”-read-out Good with actual day and time
(see above)
2. Operational status Refer to the explanation of texts
at the top of this page
3. Technical read-out Actual water ow
temperature. (T1 in °C)
and water pressure
(P in bar).
See other side
R
OK
-
+
R
OK
-
+
Standby
Good
we 10:17
20.0 °C
1.65 bar
OK
-
+
OK
-
+
User manual
8G.52.91.03 / 04.13 Changes reserved. E.&O. E.
0310 384
A B C D
E F G H
1

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw A.O. Smith Upsilon UB-70 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van A.O. Smith Upsilon UB-70 in de taal/talen: Engels als bijlage per email.

De handleiding is 1,01 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Andere handleiding(en) van A.O. Smith Upsilon UB-70

A.O. Smith Upsilon UB-70 Aanvulling / aanpassing - Nederlands - 2 pagina's

A.O. Smith Upsilon UB-70 Gebruiksaanwijzing - Nederlands - 2 pagina's

A.O. Smith Upsilon UB-70 Installatiehandleiding - Nederlands - 72 pagina's

A.O. Smith Upsilon UB-70 Installatiehandleiding - English - 68 pagina's

A.O. Smith Upsilon UB-70 Aanvulling / aanpassing - English - 2 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info