Power
When connecting the cable
to the device, turn the bayo-
net connector 90° clockwise
until it clicks into place.
Use only the supplied power
adapter.
VDSL
LANCOM, LANCOM Systems and LCOS are registered trademarks. All other names or descriptions used may be trademarks or registered trademarks of their owners. Subject to change without notice. No liability for
technical errors and/or omissions. 111530/0816
4
Please observe the fol-
lowing when setting up
the device
a For devices to be
operated on the
desktop, please attach
the adhesive rubber
footpads
a Do not rest any objects
on top of the device
a Keep the ventilation
slots on the side of
the device clear of
obstruction
a In case of wall
mounting, use the
drilling template as
supplied
a Rack installation with
the optional LANCOM
Rack Mount (not
supplied)
LANCOM 1681V
Power
VDSL
Online
ETH 1
ETH 2
VPN
ETH 3
ETH 4
ISDN Status
Hardware
Power supply 12 V DC, external power adapter (230 V); bayonet connector to secure against disconnection
Power consumption Max. ca. 14 W
Environment Temperature range 0 – 40°C, humidity 0 – 95%,non-condensing
Housing Robust synthetic housing, rear connectors, ready for wall mounting,
Kensington lock; measures 210 x 45 x 140 mm (W x H x D)
Number of fans None; fanless design, no rotating parts, high MTBF
Interfaces
LANCOM 730VA over ISDN
WAN: VDSL2
a VDSL2 as per ITU G.993.2; profiles 8a, 8b, 8c, 8d, 12a, 12b, 17a
a Compatible to VDSL2 from Deutsche Telekom
a Compliant to: ADSL2+ over ISDN as per ITU G.992.5 Annex B with DPBO, ADSL2 over
ISDN as per ITU G.992.3/5 Annex B/J, ADSL over ISDN as per ITU G.992.1 Annex B
a Supports just one virtual connection at a time in ATM (VPI-VCI pair)
ETH 4 individual ports, 10/100/1000 Mbps Gigabit Ethernet, by default set to switch mode. Up to 3
ports can be operated as additional WAN ports. Ethernet ports can be electrically disabled in
the LCOS configuration.
Config (Com) Serial configuration interface / COM port (8-pin Mini-DIN):
9,600 – 115,000 baud, suitable for optional connection of analog/GPRS modems. Supports
internal COM-port server and provides transparent asynchronous serial-data transfer via TCP.
WAN protocols
VDSL, ADSL, Ethernet PPPoE, PPPoA, IPoA, Multi-PPPoE, ML-PPP, PPTP (PAC or PNS) and IPoE (with or without
DHCP), RIP-1, RIP-2, VLAN, GRE, L2TPv2 (LAC or LNS), IPv6 over PPP (IPv6 and IPv4/IPv6 dual
stack session), IP(v6)oE (autoconfiguration, DHCPv6 or static)
Declaration of conformity
For the declaration of conformity, see the product page on our website www.lancom-systems.eu
Package content
Manual Hardware Quick Reference (DE/EN),
Installation Guide (DE/EN)
Cable 1 DSL cable for an IP-based line, 4.25m
Power adapter External power supply adapter (230 V), NEST 12 V/1.5 A DC/S, barrel connector 2.1/5.5 mm
bayonet,
LANCOM Art.-No. 110723 or 111301 (EU,230V);
LANCOM Art.-No. 110829 or 111302 (UK, 230V)
LANCOM 730VA
DSL
ETH 2
Power
ETH 1
Online
ETH 4
ETH 3
a Power
Off Device switched off
Green on,
permanently
Device operational
Blinking
green/orange
Configuration password not set. Without a
configuration password, the configuration
data in the device is unprotected.
Blinking red Charge or time limit reached
b Online
Off WAN connection inactive
Green on,
permanently
WAN connection active
Red on,
permanently
WAN connection error
d ETH
Off No networking device attached
Green on,
permanently
Connection to network device operational,
no data traffic
Flickering green Data transmission
a b c d
S E T T I N G U P A N D C O N N E C T I N G T H E D E V I C E
T E C H N I C A L D A T A
LANCOM 730VA
Quick Reference Guide
This product contains separate modem firmware with open-source software components. These are subject to their
own licenses, in particular the General Public License (GPL). The license text for the modem firmware is available at
http://www.lancom-systems.de/docs/GPL/LC-DSL-Modem-Firmware-License-EN.txt. If the respective license demands,
the source files for the corresponding software components will be made available on a download server upon request.
Serial interface
Configuring the device via
the serial interface requires
a serial configuration cable
(available as an accessory).
Ethernet interface
Use the cable to connect one of
the interfaces ETH 1 to ETH 4 to
your PC or a LAN switch.
VDSL interface
Use the supplied DSL
cable for the IP-based
line to connect the VDSL
interface and the provider's
telephone socket. For
more information, please
contact your Internet service
provider.
ba
c
d
a cb d
c DSL
Off Interface deactivated
Green, on (constant) DSL connection active
Green, flickering DSL data transfer
Red, flickering DSL transfer error
Red/orange, blinking DSL hardware error
Orange, blinking DSL training
Orange, on (perma-
nently)
DSL sync
Green, blinking DSL connecting

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Lancom 730VA bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Lancom 730VA in de taal/talen: Engels als bijlage per email.

De handleiding is 0,37 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Andere handleiding(en) van Lancom 730VA

Lancom 730VA Installatiehandleiding - Deutsch - 18 pagina's

Lancom 730VA Snelstart handleiding - Deutsch - 1 pagina's

Lancom 730VA Installatiehandleiding - English - 18 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info