Press PRICE key once and release after finish Setting price 1. Setting price 2, repeat above steps.
5. Max load alarm set
Long press MODE key under current (AMP) display mode to enter Max load alarm set. Press SET the Max load will flash,Press UP
key to set Max load alarm.The buzzer will give off “BEEP” sound and MAX LOAD will flash the when the load exceed the setting load,
The buzzer will stop and MAX LOAD will stop flash untill the load less than the setting load.
6. The scale of to KG GAS/KWH set
Long press MODE key under KG GAS/KWH display mode to enter scale of KG GAS/KWH set. Press SET key the KG GAS/KWH
will flash,Press UP key to set Max load alarm.
The scale of KG GAS/KWH,you can inquire department of energy.
7. Channel-select
Channel-select: conduct channel-select for 1,2 or 3 remotes before using them.Channel-select steps:
(1)Load main set battery,long press the CODE key,1
st
channel-select,wireless reception displays1 “- -:- -”.Plug the 1
st
remote
transmitter into power socket, long press the SET key after the LED of transmitter flash six time automatic,the 1 will display the electrical
data if channel-select succeed.
(2)Short press the CODE key again, enter the 2
nd
channel-select, long press the CODE key,wireless reception displays2 “- -:- -”.Plug
the 2
nd
remote transmitter into power socket, long press the SET key after the LED of transmitter flash six time automatic,the 2
will
display the electrical data if channel-select succeed.
(3)Short press the CODE key again, enter third channel-select, long press the CODE key,wireless reception displays 3 “- -:- -”.Plug
the third remote transmitter into power socket, long press the SET key after the LED of transmitter flash six time automatic,the 3 will
display the electrical data if channel-select succeed.
Then you can place the main set up to 30m away from the remoet set.
Corresponding data(000) will display as follow when failing to receive the remote data ,Most of the time the unit will repeating
receive the remote signal till the correct data displays.However,if corresponding data(000) continue to occur, the following may also be
the reason:
(a).The main set has been placed outside of the effective transmission range( more than 30 meters).Please move the main set closer
to the remote set.
(b).The remote may have outside interference that is preventing proper transmission.Sources of the interference include but are not
limited to metal surfaces,electrical devices,ect. The remote may need to be relocated if interference continues.
(c).Low battery.Please change the battery if it used for too long time, repeat the step (1), (2), (3) to reselect channel after
change battery.
III. Care of the product
Wipe off any dirt using a soft cloth, dipped in mild detergents, wipe off any dirt using a soft dry cloth,Avoid placing the uints in
prolonged direct sun,wind chill,rain or high humidity-position.Secure the uints to avoid dorpping-excessive force which will permanently
damage the uints.Do not tamper with the internal components.Always read the instructions in full before operating the uints.Failure to
follow these care guidelines will invalidate the warranty on the uints.
IV. Technical features
1 Indoor Testing temperature scope -10
o
C ~ +40
o
C
2 Testing temperature precision +/-1
o
C
3 Testing humidity scope 30%RH ~ 95%RH
4 Testing humidity precision +/-5% in the range of 40%~80%
+/-8% in the range of 30%~40% or 80%~95%
5 Clock precision +/-1minute/month
6 Wireless transmission and reception frequency RF433.92MHz
7 Effective distance of wireless transmission and reception Maximum 30M in open space
8 Main set power supply 4.5V(3 pieces AA/UM3/LR6 size 1.5V battery)
9 Battery life about 3 months without AC power
10 Remote power supply 230V/50Hz
11 Measure voltage range 190-276V AC
12 Measure voltage accuracy +/-1%
13 Measure current range 0.02-16A
14 Measure current accuracy +/-1% or +/-0.01A
15 Measure power range 0.5-4416W
16 Measure power accuracy +/-1% or +/-0.5W
17 Accumulative electric quantity range 0 -9999.9Kwh
18 Greenhouse gas emossion range 0 -9999.9KG
EMG-2T,EMF-2T, EMD-2T,EMI-2T,EMIS-2T/EM-2R
2

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Elro EC11 - Wireless Energy Meter bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Elro EC11 - Wireless Energy Meter in de taal/talen: Engels als bijlage per email.

De handleiding is 0,03 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info